Keterangan :
CENTRALA - SMARTLINE 036/ 4
Fire Alam and Extinguishing Systems
Description:
SmartLine036-4 device is a conventional fire control panel in the standard 4-zone - expandable to 36 zones using a maximum of 4 modules SmartLine/ 8Z ( each expanding by 8 zone) . Small size Compact design and ease of programming and use makes the control panel is ideal for small applications, which are important aspects of fast installation and programming applications.
SmartLine036-4 module can be equipped with fire SmartLetLoose / ONE. This module meets the EN12094-1 standard and offers a full range of operation for the management of the fire.
SmartLine036-4 has supervised outputs for alarm and fault signals ( the efficiency of these outputs are continuously monitored) .
The control panel provides an additional terminal on the zone configurable as: open-collector output, output supervised, monitored input, the gas sensor input interface 4-20 mA, the gas sensor input interface open collector outputs. This flexibility greatly increases the scope of SmartLine036-4.
Information about the system provides a graphical display and LED on the control panel. SmartLine036-4 manages the bus 485, which can connect up to 4 elevated terminals ( model SmartLetUSee / LCD) .
Terminal repeat all of the data gained from the central fire and allow the user to access and control system in accordance with its powers. Programming system in the control panel is simple and hassle-free by displaying the user to perform on the display. The system can also be programmed using the software Smart League ( downloadable here) .
Specifications:
Conventional fire panel with 4 zones, expandable to 36 zones
EN54 approved
Complies with EN12094-1 ( Module extinguishing)
Supports up to 32 devices per loop
Managed by the extinguishing system SmartLetLoose / ONE ( compliance with EN12094-1) ( module)
Provides support for 4 terminals learned
A supervised alarm output ( NAC)
1 output for activating the dialer
1 isolated output failure
1 isolated output fault
An additional output power
A power supply output resetowalne
1 terminal on the zone configurable as: open-collector output, controlled output, controlled entrance, entrance gas detector with 4-20mA output interfaces, the input gas detector interface open collector outputs
Relay to disconnect the battery from discharging too intense
Backlit graphic display
Navigation keys for easy access to the functions displayed graphically
RS 485 Interface for communication with terminals acquired in
Buzzer ( to ensure sound signals)
RS 232 to download / upload data
Windows Software
Easy programming via control panel
Access key for the function at level 2 ( in line with EN54)
Connector on the front panel for connection of the thermal probe
Testing the battery life
Metal housing
Main power supply 230VAC? 10%
Switch mode power supply / charging Acc. 4A@ 27.6Vdc
Place the two rechargeable 12V, 17Ah
Dimensions ( HxWxD) : 497x380x87mm
Weight ( without batteries) : 6Kg