    ATOMIC ABSORPTION SPECTROPHOTOMETER ( AAS )

    WFX- 210 Fully Automatic Flame/ Graphite Furnace
    Manufacturer : RAYLEIGH
    ISO 9001: 2000 & ISO 4001: 2004
    CE-TUV

    Innovated flame analysis technique.
    The patented flame analysis technique adopting oxygen-rich air-acetylene flame as substitution for nitrous oxide-acetylene flame for high temperature element analysis, such as Ca, Al, Ba, Mo, Ti etc.
    Flame temperature is continuously adjustable between 2300 - 2950pC which make it possible to choose the best atomization temperature for different elements. It features easy operation, low analysis cost and wide flame analytical range.
    Rich Oxygen flame will not pollute the environment and is not hurmfull to human bodies, It’ s break-through in flame AAS analysis

    Automatic hollow cathode lamp changeover. The high performance HCL can be used directly.
    Auto-changeover and position optimization of integrated flame/ graphite furnace atomizer.
    Light-controlled graphite furnace power supplier, adopting FUZZY-PID temperature control technique and dual curve working mode, ensures fast heating, accurate and stable temperature control and good temperature reproducibility. Temperature auto-correction function provided.
    Graphite furnace with pneumatic control and pressure lock ensures constant pressure and reliable contact.
    High accuracy and reproducibility of the graphite furnace auto-sampler, realizing fully automation of graphite furnace analysis.
    Auto-ignition, automatic spectral bandwidth selection.
    Fully automated wavelength scanning and peaking
    Automatic setting of Gas flow
    Perfect safety protection measures, alarm and automatic safety protection to fuel gas leakage, air pressure deficiency and abnormal flame extinction; spray chamber made of explosion-proof material, all-titanium burner and explosion-proof stopper for flame analyses; alarm and protection function to argon pressure deficiency, insufficient cooling water supply, over-heating and over-current etc. in graphite furnace analyses.
    Adopting large-scale programmable logic array and Inter IC bus technique and highly reliable adapters for electric design.
    Standard RS-232 serial interface communication

    Easy and flexible WINDOWS operating system, with multi-windows processing technology to observe the signal profile, the measured results and the calibration curve at the same time. Various analytical programs, data, signals and graphics can all be stored for later use.

    Specifications

    Main Specification
    Wavelength range
    190-900nm

    Wavelength accuracy
    Better than ± 0.25nm

    Resolution
    Two spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30% .

    Baseline stability
    0.004A/ 30min

    Background correction
    The D2 lamp background correction capability at 1A is better than 30 times The S-H background correction capability at 1.8A is better than 30 times.
    Light Source System
    Lamp turret
    Motorized 6-lamp turret ( Two high performance HCLs can be mounted on the turret to increase the sensitivity in flame analysis.) ; auto alignment; auto fine adjustment; fully automated scan and peak-picking

    Lamp current adjustment
    Automatic adjustment and display.
    Wide pulse current: 0~ 25mA,
    Narrow pulse current: 0~ 10mA.

    Lamp power supply mode
    Powered by two pulses ( wide and narrow) simultaneously.

    Optical System
    Monochomator
    Single beam, Czerny-Turner design grating monochromator

    Grating
    1800 l/ mm

    Focal length
    277mm

    Blazed Wavelength
    250nm

    Spectral Bandwidth
    0.1nm, 0.2nm, 0.4nm, 1.2nm, auto-switch over

    Atomizer
    Flame/ Graphite Furnace
    Flame & Graphite Furnace atomizer automatic changeover
    Automatic graphite furnace position optimization, automatic flame height setting and horizontal position optimization.
    Automatic gas flow setting, alarm and automatic protection function for gas leak, abnormal flow, air-pressure deficiency and abnormal flame extinction, automatic ignition.

    Graphite Furnace Autosampler
    Sample tray capacity
    55 sample cups and 5 cups for matrix modifier

    Material of the sample cup
    Polypropylene

    Volume of the standard cup
    3ml for sample, 20ml for matrix modifier

    Number of repeatable measurements
    Up to 99 times

    Sampling system
    100ul and 1ml injectors, large flow sampling nozzle rinsing.

    Sampling precision and repeatability
    Precision: 1% ; Repeatability: 0.3% for min. sampling volume.

    Auto-correction
    Sampling nozzle auto-correction, sample cup height auto correction.
    Detection and Data Processing System
    Detector
    R928 Photomultiplier with high sensitivity and wide spectral range.

    Software
    Windows 98/ Windows operating system

    Analytical method
    Working Curve Method ( 1st order and 2nd order fitting) with automatic sensitivity correction; Standard Addition Method.

    Concentration
    Auto-calculation of concentration and content

    Repeatable measurement
    Repeated measurement of up to 99 times, automatic calculation of mean value, standard deviation and relative standard deviation.

    Multi-task Functions
    Sequential measurement for multi-element determination to the same sample ( Max. 6 elements) .

    Condition reading
    With model function

    Result printing
    Measurement data and final analytical report printout, editing with Excel.

    Flame Analysis
    Burner
    10cm single slot all-titanium burner

    Spray chamber
    Corrosion resistance All-plastic spray chamber.

    Nebulizer
    High efficiency glass nebulizer with metal sleeve. Sucking rate 6-7 mL/ min
    Burner
    10 cm single slot all-titanium burner

    Flame Ignition
    Automatic

    Characteristic Concentration and Detection Limit
    Air-C2H2 flame
    Oxygen-rich Air-C2H2 flame ( For WFX-210)
    Cu: Characteristic concentrationd0.025mg/ L, Detection limitd0.006mg/ L;
    Ba: Characteristic concentration d 0.22mg/ L Al: Characteristic concentration d 0.4mg/ L

    Graphite Furnace Analysis
    Temperature range
    Room temperature~ 3000º C
    Light-controlled temperature range
    1500º C -3000º C, temperature auto-correction

    Temperature control accuracy
    d1%

    Heating rate
    2000° C/ s

    Characteristic mass
    Cdd0.5 × 10-12g, Cud5 × 10-12g, Mod1× 10-11g
    Precision
    Cdd3% , Cud3% , Mod4%
    Safety protection
    Protections for over-heating, over-current, and less cooling water and argon pressure monitoring functions
    Function Expansion
    Hydride Vapor Generator can be connected for hydride analysis
    Dimensions and Weight
    Main Unit
    107x49x55cm, 140 kg

    Graphite furnace
    42x42x46, 65kg

    Autosampler
    40x29x29cm, 15kg