    ATOMIC ABSORPTION SPECTROPHOTOMETER ( AAS ) , RAYLEIGH WFX-310/ 320

    Harga:
    Harga promosi
    Jumlah Pesanan:
    Negara Asal:
    China
    Cara Pembayaran:
    Tunai
    Kemas & Pengiriman:
    Unit

    Keterangan :

    WFX-310/ 320 Flame Atomic Absorption Spectrophotometer ( AAS )

    Manufacturer : RAYLEIGH
    ISO 9001: 2000 & ISO 4001: 2004
    CE-TUV GmbH

    Features:
    High cost-effective flame AAS
    Reasonable design, adopting the same key parts as in high end instruments, ensures basic functions but less automation to provide an economic model for users.
    Reliable integration of main unit with microprocessor
    Built-in microprocessor with necessary auto-control and data processing functions achieve high reliability of the instrument
    Simple and easy operation
    Eye-catching digital display, multi-function data processing ability and fast function-key direct input realize easy and fast analyses.

    Main Specification
    Wavelength range 190-900nm
    Wavelength accuracy Better than ¡ à 0.25nm
    Resolution Two spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30% .
    Baseline stability 0.005A/ 30min
    Background correction The D2 lamp background correction capability at 1A is better than 30 times
    Light Source System 2 lamps are powered simultaneously ( one preheating )
    Lamp current adjustment 0 ~ 20 mA
    Lamp power supply mode powered by 400Hz square pulse
    Optical System
    Monochomator Single beam, Czerny-Turner design grating monochromator
    Grating 1800 l/ mm
    Focal length 277mm
    Blazed Wavelength 250nm
    Spectral Bandwidth 0.1nm, 0.2nm, 0.4nm, 1.2nm 4 steps
    Adjustment Manual adjustment for wavelength and slit
    Flame Atomizer
    Burner 10cm single slot all-titanium burner
    Spray chamber Corrosion resistant all-plastic spray chamber
    Nebulizer High efficiency glass nebulizer with metal sleeve, sucking up rate: 6-7ml/ min
    Position adjustment manual adjusting mechanism for vertical, horizontal positions and rotation angle of the burner
    Gas lone protection Fuel gas leakage alarm
    Detection and Data Processing System
    Detector R928 Photomultiplier with high sensitivity and wide spectral range
    Electronic and micro-comp uter Automatic adjustment of light source power. light energy and negative high voltage auto-balace
    Display mode LED display of energy and measurement values, concentration direct reading
    Read mode Transient, time average, peak height, peak area. Integral time is selectable in the range of 0.1 â 19.9s
    Scale expansion 0.1 ~ 99
    Data processing mode Automatic calculation of mean, standard deviation and relative standard deviation. Repeating number is in the range of 1~ 99
    Measurement mode Automatic curve fitting with 3~ 7 standards; Sensitivity auto-correction.
    Result printing Measurement data, working curve, signal profile and analytical condition can all be print out
    Instrument self-check Check current status of each function key
    Characteristic Concentration and Detection Limit
    Air-C2H2 flame Cu: Characteristic concentration¡ à 0.025mg/ L, Detection limit¡ à 0.006mg/ L;
    Function Expansion Hydride vapor generator can be connected for hydride analysis
    Dimensions and weight
    Main unit 102¡ à 49¡ à 54cm, unpacked 80kg