Load Cell : FS1 series[29 Oct. 2009, 19:33:26]
Feature
* Aluminium full bridge gage load cell
Specifications
Rated output 19.61 N { 2 kgf} ~ 196.1 N { 20 kgf}
Safe overload 150 % R.C.
Rated output -1.58 mV/ V± 0.158 mV/ V
~ -2.14 mV/ V± 0.214 mV/ V
Non-linearity 0.05 % R.O.
Hysteresis 0.05 % R.O.
Repeatability 0.05 % R.O.
Creep 0.15 % R.O./ 1 min
Creep recovery 0.15 % R.O./ 1 min
Excitation, recommended 5 V or less
Excitation, maximum 8 V
Zero balance ± 1 mV/ V
Input resistance 350 © ± 35 ©
Output resistance 350 © ± 35 ©
Insulation resistance 1 000 M© or more ( DC50 V) ( between bridge and main body)
Temp. range, compensated -10 ~ 50
Temp. range, safe -10 ~ 50
Temp. effect on zero 1 % R.O./ 10
Temp. effect on output 1 % LOAD/ 10
Class of protection IP00
Material of element Alluminium alloy
Durability 1 000 000 times with rated load applied.