CC1-Z series[30 Oct. 2009, 21:01:10]
* Canister type, suitable for high explosion risk environment such as with flammable liquid or gas, or in pharmaceutical or petrochemical application.
Passing No. of model authorization
CCP1-200K ~ 1T-Z : No.37835
CCP1-2T ~ 5T-Z : No.37836
CCP1-10T-Z : No.37837
CCP1-20T-Z : No.37838
CCP1-30T-Z : No.37839
CCP1-50T-Z : No.37840
Classification of explosive & flammability 2G4
Hazardous areas to be used 1 zone and 2 zone
Limit of temperature raise at operation
70 ( In case of operating temperature at 40 )
Specifications
Rated capacity 1.961 kN { 200 kgf} ~ 196.1 kN { 20 tf}
Safe overload 150 % R.C.
Ultimate overload 200 % R.C.
Rated output 2.8 mV/ V± 0.002 8 mV/ V
( CCP1-2T~ 20T-Z : 3 mV/ V± 0.003 mV/ V)
Non-linearity 0.05 % R.O.
Hysteresis 0.02 % R.O.
Repeatability 0.02 % R.O.
Excitation, recommended 12 V or less
Excitation, maximum 20 V
Zero balance ± 0.028 mV/ V ( CCP1-2T~ 20T-Z : 0.03 mV/ V)
Input resistance 350 © ± 3.5 ©
Output resistance 350 © ± 5 ©
Insulation resistance 2 000 M© or more ( DC50 V) ( between bridge and main body)
Temp. range, compensated -10 ~ 70
Temp. range, safe -20 ~ 100
Temp. effect on zero 0.03 % R.O./ 10
Temp. effect on output 0.03 % LOAD/ 10
Cable CAB-501 should be used. ( Option)
( Æ 10, 6-cores shielded cable is attached.)
Class of protection IP64
Material of element Alloy steel
Paint Painted with epoxy resin.
( Munsell 6GY3.5/ 2 half-polished resemblance color)
Durability 1 000 000 times with rated load applied.
Terminal box Fixed with solderless terminal screws on the terminal plate
Cable retracting method Explosion-proof packing type
Piping method Thick steel conduit tube