Keterangan
• Mirrored scale for easy and accurate reading.
• Fuse and diode protected circuit (except 15A AC range).
• Output terminal to cut off DC component when measuring AC voltage.
• Safety designed input terminals and test leads.
Do not make voltage measurements on industry power lines of 250V
or higher.
DC V : 0.5/5/25/100/250/500V (5k©/V)
|±3% of FS
AC V : 10/50/250/500V (2.5k©/V)
|±3% of FS
DC A : 200µA/2.5/25/250mA
|±3% of FS
|±5% of FS (250mA)
© : 3/30/300k©
|±3% of scale length
Temperature : -20ºC~+150ºC
|±5ºC (0ºC~+100ºC)
|±10ºC (other ranges)
(with the use of Temperature probe 7060)
Battery Test : 2V (20© load)
Withstand Voltage : 3000V AC for 1 minute
Power Source : R6P (AA) (1.5V) × 1
Dimensions : 130(L) × 85(W) × 38(D)mm
Weight : 175g approx.
Accessories : 7066 (Test Leads)
8901 (0.5A/250V fuse) × 1
R6P (AA) × 1
Instruction Manual
Optional : 9059 (Carrying Case)
7060 (Temperature Probe)